CM-X300 CoM
24 CM-X300 Reference Guide Rev 1.31 30-Dec-2010
Figure 4 Magnetic Interconnect Schematic
Figure 5 DC Source for Magnetic Center Taps
3.3.5 Serial Ports
CM-X300 incorporates 3 UARTs: one full function UART, one RX-TX only (console)
UART and one partial-function UART. All three UARTs share the same feature list, baud
rates and use the same programming model.
The UARTs share the following features:
Functionally compatible with 16550A and 16750
Ability to add or delete standard asynchronous communications bits (start, stop, and
parity) in the serial data
Independently controlled transmit, receive, line status, and data-set interrupts
Modem control functions (nCTS and nRTS on two of the three UARTs. The full-
function UART additionally has nDSR, nDTR, nRI, and nDCD signals)
Auto-flow capability controls data I/O without generating interrupts:
nRTS (output) controlled by UART Receive FIFO
nCTS (input) from modem controls UART transmitter
Programmable serial interface: